CVE-2022-37461 Detail
Current Description
Multiple cross-site scripting (XSS) vulnerabilities in Canon Medical Vitrea View 7.x before 7.7.6 allow remote attackers to inject arbitrary web script or HTML via (1) the input after the error subdirectory to the /vitrea-view/error/ subdirectory, or the (2) groupID, (3) offset, or (4) limit parameter to an Administrative Panel (Group and Users) page. There is a risk of an attacker retrieving patient information.
Analysis Description
Multiple cross-site scripting (XSS) vulnerabilities in Canon Medical Vitrea View 7.x before 7.7.6 allow remote attackers to inject arbitrary web script or HTML via (1) the input after the error subdirectory to the /vitrea-view/error/ subdirectory, or the (2) groupID, (3) offset, or (4) limit parameter to an Administrative Panel (Group and Users) page. There is a risk of an attacker retrieving patient information.
Severity
References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to [email protected].
Weakness Enumeration
CWE-ID | CWE Name | Source |
---|---|---|
CWE-79 | Improper Neutralization of Input During Web Page Generation (‘Cross-site Scripting’) | NIST |
Change History
2 change records found show changes
Initial Analysis 10/04/2022 12:29:32 PM
Action | Type | Old Value | New Value |
---|---|---|---|
Added | CPE Configuration |
OR *cpe:2.3:a:canon:medical_vitrea_view:*:*:*:*:*:*:*:* versions from (including) 7.0 up to (excluding) 7.7.6 |
|
Added | CVSS V3.1 |
NIST AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N |
|
Added | CWE |
NIST CWE-79 |
|
Changed | Reference Type |
https://www.trustwave.com/en-us/resources/security-resources/security-advisories/?fid=30693 No Types Assigned |
https://www.trustwave.com/en-us/resources/security-resources/security-advisories/?fid=30693 Exploit, Third Party Advisory |
Changed | Reference Type |
https://www.vitalimages.com/customer-success-support-program/vital-images-software-security-updates/ No Types Assigned |
https://www.vitalimages.com/customer-success-support-program/vital-images-software-security-updates/ Vendor Advisory |
Changed | Reference Type |
https://www.vitalimages.com/vitrea-vision/vitrea-view/ No Types Assigned |
https://www.vitalimages.com/vitrea-vision/vitrea-view/ Product, Vendor Advisory |
CVE Modified by MITRE 9/30/2022 8:15:09 PM
Action | Type | Old Value | New Value |
---|---|---|---|
Added | Reference |
https://www.vitalimages.com/customer-success-support-program/vital-images-software-security-updates/ [No Types Assigned] |
Quick Info
CVE Dictionary Entry:
CVE-2022-37461
NVD Published Date:
09/30/2022
NVD Last Modified:
10/04/2022
Source:
MITRE