A security vulnerability has been identified in HPE SimpliVity 380 Gen 9, HPE SimpliVity 380 Gen 10, HPE SimpliVity 380 Gen 10 G, HPE SimpliVity 2600 Gen 10, SimpliVity OmniCube, SimpliVity OmniStack for Cisco, SimpliVity OmniStack for Lenovo and SimpliVity OmniStack for Dell nodes. An API is used to execute a command manifest file during upgrade does not correctly prevent directory traversal and so can be used to execute manifest files in arbitrary locations on the node. The API does not require user authentication and is accessible over the management network, resulting in the potential for unauthenticated remote execution of manifest files. For all customers running HPE OmniStack version 3.7.9 and earlier. HPE recommends upgrading the OmniStack software to version 3.7.10 or later, which contains a permanent resolution. Customers and partners who can upgrade to 3.7.10 should upgrade at the earliest convenience. For all customers and partners unable to upgrade their environments to the recommended version 3.7.10, HPE has created a Temporary Workaround https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=mmr_sf-EN_US000061901&withFrame for you to implement. All customer should upgrade to the recommended 3.7.10 or later version at the earliest convenience.

Source:  MITRE
View Analysis Description

Analysis Description

A security vulnerability has been identified in HPE SimpliVity 380 Gen 9, HPE SimpliVity 380 Gen 10, HPE SimpliVity 380 Gen 10 G, HPE SimpliVity 2600 Gen 10, SimpliVity OmniCube, SimpliVity OmniStack for Cisco, SimpliVity OmniStack for Lenovo and SimpliVity OmniStack for Dell nodes. An API is used to execute a command manifest file during upgrade does not correctly prevent directory traversal and so can be used to execute manifest files in arbitrary locations on the node. The API does not require user authentication and is accessible over the management network, resulting in the potential for unauthenticated remote execution of manifest files. For all customers running HPE OmniStack version 3.7.9 and earlier. HPE recommends upgrading the OmniStack software to version 3.7.10 or later, which contains a permanent resolution. Customers and partners who can upgrade to 3.7.10 should upgrade at the earliest convenience. For all customers and partners unable to upgrade their environments to the recommended version 3.7.10, HPE has created a Temporary Workaround https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=mmr_sf-EN_US000061901&withFrame for you to implement. All customer should upgrade to the recommended 3.7.10 or later version at the earliest convenience.

Source:  MITRE

Severity

CVSS 3.x Severity and Metrics:

CVSS 2.0 Severity and Metrics:

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to [email protected].

Weakness Enumeration

CWE-ID CWE Name Source
CWE-22 Improper Limitation of a Pathname to a Restricted Directory (‘Path Traversal’) NIST  

Known Affected Software Configurations Switch to CPE 2.2

Configuration 1 ( hide )

 cpe:2.3:o:hp:simplivity_380_gen9_firmware:*:*:*:*:*:*:*:*
     Show Matching CPE(s)
From (including)
3.6.2
Up to (including)
3.7.9
 cpe:2.3:h:hp:simplivity_380_gen9:-:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 2 ( hide )

 cpe:2.3:o:hp:simplivity_380_gen10_g_firmware:*:*:*:*:*:*:*:*
     Show Matching CPE(s)
From (including)
3.7.8
Up to (including)
3.7.9
 cpe:2.3:h:hp:simplivity_380_gen10_g:-:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 3 ( hide )

 cpe:2.3:o:hp:simplivity_380_gen10_firmware:*:*:*:*:*:*:*:*
     Show Matching CPE(s)
From (including)
3.7.1
Up to (including)
3.7.9
 cpe:2.3:h:hp:simplivity_380_gen10:-:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 4 ( hide )

 cpe:2.3:o:hp:simplivity_2600_gen10_firmware:*:*:*:*:*:*:*:*
     Show Matching CPE(s)
From (including)
3.7.5
Up to (including)
3.7.9
 cpe:2.3:h:hp:simplivity_2600_gen10:-:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 5 ( hide )

 cpe:2.3:o:hp:simplivity_omnicube_firmware:*:*:*:*:*:*:*:*
     Show Matching CPE(s)
From (including)
3.5.2
Up to (including)
3.7.9
 cpe:2.3:h:hp:simplivity_omnicube:-:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 6 ( hide )

 cpe:2.3:o:hp:simplivity_omnistack_for_dell_firmware:*:*:*:*:*:*:*:*
     Show Matching CPE(s)
From (including)
3.5.2
Up to (including)
3.7.9
 cpe:2.3:h:hp:simplivity_omnistack_for_dell:-:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 7 ( hide )

 cpe:2.3:o:hp:simplivity_omnistack_for_cisco_firmware:*:*:*:*:*:*:*:*
     Show Matching CPE(s)
From (including)
3.5.2
Up to (including)
3.7.9
 cpe:2.3:h:hp:simplivity_omnistack_for_cisco:-:*:*:*:*:*:*:*
     Show Matching CPE(s)

Configuration 8 ( hide )

 cpe:2.3:o:hp:simplivity_omnistack_for_lenovo_firmware:*:*:*:*:*:*:*:*
     Show Matching CPE(s)
From (including)
3.5.2
Up to (including)
3.7.9
 cpe:2.3:h:hp:simplivity_omnistack_for_lenovo:-:*:*:*:*:*:*:*
     Show Matching CPE(s)

Change History

1 change record found – show changes

Initial Analysis1/17/2020 4:17:07 PM

Action Type Old Value New Value
Added CPE Configuration
AND
     OR
          *cpe:2.3:o:hp:simplivity_2600_gen10_firmware:*:*:*:*:*:*:*:* versions from (including) 3.7.5 up to (including) 3.7.9
     OR
          cpe:2.3:h:hp:simplivity_2600_gen10:-:*:*:*:*:*:*:*
Added CPE Configuration
AND
     OR
          *cpe:2.3:o:hp:simplivity_380_gen10_firmware:*:*:*:*:*:*:*:* versions from (including) 3.7.1 up to (including) 3.7.9
     OR
          cpe:2.3:h:hp:simplivity_380_gen10:-:*:*:*:*:*:*:*
Added CPE Configuration
AND
     OR
          *cpe:2.3:o:hp:simplivity_380_gen10_g_firmware:*:*:*:*:*:*:*:* versions from (including) 3.7.8 up to (including) 3.7.9
     OR
          cpe:2.3:h:hp:simplivity_380_gen10_g:-:*:*:*:*:*:*:*
Added CPE Configuration
AND
     OR
          *cpe:2.3:o:hp:simplivity_380_gen9_firmware:*:*:*:*:*:*:*:* versions from (including) 3.6.2 up to (including) 3.7.9
     OR
          cpe:2.3:h:hp:simplivity_380_gen9:-:*:*:*:*:*:*:*
Added CPE Configuration
AND
     OR
          *cpe:2.3:o:hp:simplivity_omnicube_firmware:*:*:*:*:*:*:*:* versions from (including) 3.5.2 up to (including) 3.7.9
     OR
          cpe:2.3:h:hp:simplivity_omnicube:-:*:*:*:*:*:*:*
Added CPE Configuration
AND
     OR
          *cpe:2.3:o:hp:simplivity_omnistack_for_cisco_firmware:*:*:*:*:*:*:*:* versions from (including) 3.5.2 up to (including) 3.7.9
     OR
          cpe:2.3:h:hp:simplivity_omnistack_for_cisco:-:*:*:*:*:*:*:*
Added CPE Configuration
AND
     OR
          *cpe:2.3:o:hp:simplivity_omnistack_for_dell_firmware:*:*:*:*:*:*:*:* versions from (including) 3.5.2 up to (including) 3.7.9
     OR
          cpe:2.3:h:hp:simplivity_omnistack_for_dell:-:*:*:*:*:*:*:*
Added CPE Configuration
AND
     OR
          *cpe:2.3:o:hp:simplivity_omnistack_for_lenovo_firmware:*:*:*:*:*:*:*:* versions from (including) 3.5.2 up to (including) 3.7.9
     OR
          cpe:2.3:h:hp:simplivity_omnistack_for_lenovo:-:*:*:*:*:*:*:*
Added CVSS V2
NIST (AV:N/AC:L/Au:N/C:P/I:P/A:P)
Added CVSS V3.1
NIST AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Added CWE
NIST CWE-22
Changed Reference Type
https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbst03956en_us No Types Assigned
https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbst03956en_us Vendor Advisory